| Inverter(Off Grid) |
| Inverter(On Grid) |
| Battery |
|
1KW Controller and Inverter

Model No. |
WWSI1010-48 |
WWSI1010-48(city electric switch) |
Output Power |
1KW |
1KW |
Max Wind Power Input |
1KW |
1KW |
Max Solar Power Input |
300W |
300W |
Rated Battery Voltage |
48V DC |
48V DC |
Floating Charge Voltage |
56 V DC |
56 V DC |
Over Voltage Shutdown |
68 V DC |
68 V DC |
Over Voltage Recovery |
66 V DC |
66 V DC |
Under Voltage Shutdown |
42 V DC |
42 V DC |
Under Voltage Recovery |
48 V DC |
48 V DC |
No Load Loss |
0.4A |
0.4A |
Pure Sine Wave |
Output Vac |
220 V AC |
110 V AC |
Total Harmonic Distortion |
≤4 % |
Display Method |
LCD |
Output Frequency |
50 Hz±0.05Hz |
Inverting Efficiency |
Max. 90% |
Overload Ability |
120% ,1min 150% 10S |
Noise ( 1m ) |
≤40dB |
Dielectric Strength |
1500V AC ,1min |
Operation Ambient Temperature |
-10 ~ 50℃ |
Protection Type
|
high battery, low battery, over load , short circuit, over
temperature, pole-confusion protection for storage battery, automatic dump-load function. |
Cooling Method |
By Fan |
Size(W×H×D)mm |
470×410×230(controller and inverter) |
Weight(KG) |
15.5 |
2KW Wind and Solar Hybrid Controller

Model |
WWS20-48 |
WWS20-96 |
WWS20-120 |
Max Wind Input Power |
2KW |
Max PV Input Power |
600W |
Rated Battery Voltage |
48V |
96V |
120V |
Floating Charge Voltage |
56V |
112V |
140V |
Display Method |
LCD |
Display Parameter |
Battery Voltage, Charging Current |
Size(W×H×D)mm |
470×230×410 |
Weight ( KG ) |
12 |
11 |
Protection Type |
Pole-confusion protection, automatic dump-load function. |
2KW Pure Sine Wave Inverter

Model |
WI20-48 |
WI20-96 |
WI20-120 |
WI20-220 |
WI20-240 |
Rated Output Capacity |
2kVA |
Rated Battery Voltage |
48V DC |
96V DC |
120V DC |
216V DC |
240V DC |
Over Voltage Point |
68V DC |
134V DC |
170V DC |
306V DC |
340V DC |
Over Voltag Recovery Point |
66V DC |
132V DC |
160V DC |
297V DC |
320V DC |
Under Voltage Point |
42V DC |
84V DC |
105V DC |
189V DC |
210V DC |
Under Voltage Recovery Point |
48V DC |
96V DC |
120V DC |
216V DC |
240V DC |
No Load Loss |
0.4A |
0.2A |
0.15A |
0.1A |
0.1A |
Output Waveform |
Pure Sine Wave |
Display Method |
LCD |
Display Parameter |
Battery Voltage, Output Voltage, State Parameter |
Cooling Method |
Fan |
Rated Output Voltage |
110/120/220/230/240 V AC |
Total Harmonic Distortion |
≤4 % |
Output Frequency |
50/60 Hz±0.05Hz |
Dynamic Response |
5% |
Overload Ability |
120% one minute,150% 10 seconds |
Inverting Efficiency |
Max. 90% |
Noise ( 1m ) |
≤40dB |
Dielectric Strength |
1500V AC , one minute |
Protection Type |
Battery over voltage protection 、 Battery under voltage protection 、 Battery reverse-connect protection 、 Output over load protection 、 Output short circuit protection 、 Over temperature protection |
Operation Ambient Temperature |
-20 ~ 50℃ |
Operation Altitude |
≤ 4000m |
Operation Ambient Humidity |
0~90%,no condensing |
Size(W×H×D)mm |
470×430×300 |
Weight ( KG ) |
19.5 |
We can adjust the configurations and parameters according to customers' requirement. |
3KW Wind and Solar Hybrid Controller

Model |
WWS30-48 |
WWS30-120 |
WWS30-220 |
WWS30-240 |
Max Wind Input Power |
3KW |
Max PV Input Power |
1KW |
Rated Battery Voltage |
48V |
120V |
220V |
240V |
Floating Charge Voltage |
56V |
140V |
256V |
280V |
Display Method |
LCD |
Display Parameter |
Battery Voltage, Charging Current |
Size(W×H×D)mm |
470×230×410 |
Weight ( KG ) |
13.2 |
Protection Type |
pole-confusion protection , automatic dump-load function. |
3KW Pure Sine Wave Inverter

Model |
WI30-48 |
WI30-96 |
WI30-120 |
WI30-220 |
WI30-240 |
Rated Output Capacity |
3kVA |
Rated Battery Voltage |
48V DC |
96V DC |
120V DC |
216V DC |
240V DC |
Over Voltage Point |
68V DC |
134V DC |
170V DC |
306V DC |
340V DC |
Over Voltage Recovery Point |
66V DC |
132V DC |
160V DC |
297V DC |
320V DC |
Under Voltage Point |
42V DC |
84V DC |
105V DC |
189V DC |
210V DC |
Under Voltage Recovery Point |
48V DC |
96V DC |
120V DC |
216V DC |
240V DC |
No Load Loss |
0.46A |
0.3A |
0.17A |
0.12A |
0.12A |
Output Waveform |
Pure Sine Wave |
Display Method |
LCD |
Display Parameter |
Battery Voltage, Output Voltage, State Parameter |
Cooling Method |
Fan |
Rated Output Voltage |
110/120/220/230/240 V AC |
Total Harmonic Distortion |
≤4 % |
Output Frequency |
50/60 Hz±0.05Hz |
Dynamic Response |
5% |
Overload Ability |
120% one minute,150% 10 seconds |
Inverting Efficiency |
Max. 90% |
Noise ( 1m ) |
≤40dB |
Dielectric Strength |
1500V AC , one minute |
Protection Type |
Battery over voltage protection 、 Battery under voltage protection 、 Battery reverse-connect protection 、 Output over load protection 、 Output short circuit protection 、 Over temperature protection |
Operation Ambient Temperature |
-20 ~ 50℃ |
Operation Altitude |
≤ 4000m |
Operation Ambient Humidity |
0~90%,no condensing |
Size(W×H×D)mm |
470×430×300 |
Weight ( KG ) |
24.5 |
We can adjust the configurations and parameters according to customers' requirement. |
5KW Wind and Solar Hybrid Controller

Model |
WWS50-96 |
WWS50-120 |
WWS50-220 |
WWS50-240 |
Max Wind Input Power |
5KW |
Max PV Input Power |
2KW |
Rated Battery Voltage |
96V |
120V |
220V |
240V |
Floating Charge Voltage |
112V |
140V |
256V |
280V |
Display Method |
LCD |
Display Parameter |
Battery Voltage, Charging Current |
Size(W×H×D)mm |
(Unload box)820×250×485 (Control box) 440×210×380 |
Weight ( KG ) |
(Unload box)25.5 (Control box)10 |
Protection Type |
pole-confusion protection , automatic dump-load function. |
5KW Pure Sine Wave Inverter

Model |
WI50-96 |
WI50-120 |
WI50-220 |
WI50-240 |
Rated Output Capacity |
5kVA |
Rated Battery Voltage |
96V DC |
120V DC |
216V DC |
240V DC |
Over Voltage Point |
134V DC |
170V DC |
306V DC |
340V DC |
Over Voltage Recovery Point |
132V DC |
160V DC |
297V DC |
320V DC |
Under Voltage Point |
84V DC |
105V DC |
189V DC |
210V DC |
Under Voltage Recovery Point |
96V DC |
120V DC |
216V DC |
240V DC |
No Load Loss |
0.4A |
0.3A |
0.12A |
0.1A |
Output Waveform |
Pure Sine Wave |
Display Method |
LCD |
Display Parameter |
Battery Voltage, Output Voltage, State Parameter |
Cooling Method |
Fan |
Rated Output Voltage |
110/120/220/230/240 V AC |
Total Harmonic Distortion |
≤4 % |
Output Frequency |
50/60 Hz±0.05Hz |
Dynamic Response |
5% |
Overload Ability |
120% one minute,150% 10 seconds |
Inverting Efficiency |
Max. 90% |
Noise ( 1m ) |
≤40dB |
Dielectric Strength |
1500V AC , one minute |
Protection Type |
Battery over voltage protection 、 Battery under voltage protection 、 Battery reverse-connect protection 、 Output over load protection 、 Output short circuit protection 、 Over temperature protection |
Operation Ambient Temperature |
-20 ~ 50℃ |
Operation Altitude |
≤ 4000m |
Operation Ambient Humidity |
0~90%,no condensing |
Size(W×H×D)mm |
600×260×600 |
Weight ( KG ) |
38.5 |
We can adjust the configurations and parameters according to customers' requirement. |
|